Product Description
| Applicable Syringes | 5ml,10ml,20ml,30ml,50ml,60ml,of any standard |
| Accuracy | +/- 2% with correct calibration |
| Rate mode | 0.1ml/h-2000ml/h (0.1ml/h or1ml/h step) |
| Time Mode | SOL: VOL:0.1-9999.9ml (0.1ml step) |
| Dose Mode | Time: 00:01-99:59min (1min step) |
| Volume: 0.1-999.9ml(0.1ml step) | |
| DRUG MASS: 0.1-999.9mg (0.1mg step) | |
| DOSE: 0.001-9999 (0.001 step) | |
| WEIGHT: 0.1-300kg (0.1kg step) | |
| Total volume range | 0.1-9999.9ml (0.1ml step) |
| Purge Rate | Programmable and adjustable |
| KVO Rate | 0.0-5.0ml/h , Programmable and adjustable |
| DPS Occlusion Pressure | LOW: 60(±15)kPa, MEDIUM: 90(±15)kPa |
| Alarms | High: 120(±15)kPa (Adjustable) |
| Loose, Occlusion, Empty, Near Empty, Rate Abnormal | |
| Low Battery, No Battery, Infusion complete, No Action | |
| Syringe Plunger Disengagement | |
| Alarms volume | Three levels: LOW,MEDIUM or high |
| Bolus Rate | 0.1-2000ml/h Programmable and adjustable, Automatic/manual bolus avaliable |
| Bolus Volume | Range 1-50ml,(0.1ml step) |
| Interface | RS-232 |
| Brightness | 1-10 levels can be selected |
| History records | 2000 events stored can be checked and downloaded |
| Power Source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz |
| DC power supply:12~15V, power>15W; | |
| Built-in Lithium Battery: Rechargeable, 11.1V,2000mAh. | |
| 12 hours of continuous operation | |
| Protection Class | Class I, Type CF,IPX4 |
| Dimension/ N.W | 240mm*150mm*117mm,2.5kg |
| Packing size/G.W | 300mm*260mm*160mm,3.5KG |
single use infusion pump cheap icu portable safe electric infusion syringe pump
Power Source: Electricity
Warranty:Lifetime
After-sale Service:Return and Replacement
Material:metal, plastic
Shelf Life:3 years
Quality Certification:ceInstrument
classification:Class II
Safety standard:None
Type:single use infusion pump
Display:4.3 inches large LCD screen
Work mode:Rate/Time Volume/Dosage Weight
Net weight:2.2kg
Power:35VA
Store injection records:2000pcs
KVO Rate:0.1ml/h~5ml/h
Three levels for Occlusion:high/Middle/Low
remote control function:it has remote controller
adjust directly:speed/time/volume and drug amount
20000 Unit/Units per Year single use infusion pump
| Quantity(Units) | 1 - 20 | >20 |
| Est. Time(days) | 5 | To be negotiated |
Model Number:SP01
Power Source:Electric
Warranty:1 Year, 1 YEAR
After-sale Service:Online technical support
Material:metal, plastic
Shelf Life:1years
Quality Certification:ce
Instrument classification:Class II
Safety standard:None
Product name:syringe pump
MOQ:5PCS
Certificate:CE,ISO
Logo:Customized Logo
OEM:Avalibale
Syringe Size:10, 20, 30, 50/60 ml
Battery:9.6±1.6 V, rechargeable
Packaging Details:carton,tray,bag and so on. It will depend on the customers' needs.
| Syringe Size | 10, 20, 30, 50/60 ml |
| Applicable Syringe | Compatible with syringe of any standard |
| VTBI | 0.1-9999 ml <1000 ml in 0.1 ml increments ≥1000 ml in 1 ml increments |
| Flow Rate | Syringe 10 ml: 0.1-400 ml/h Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-900 ml/h Syringe 50/60 ml: 0.1-1300 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
| Bolus Rate | Syringe 10 ml: 400 ml/h Syringe 20 ml: 600 ml/h Syringe 30 ml: 900 ml/h Syringe 50/60 ml: 1300 ml/h |
| Anti-Bolus | Automatic |
| Accuracy | ±2% (mechanical accuracy ≤1%) |
| Infusion Mode | Flow rate: ml/min, ml/h Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
| KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
| Alarms | Occlusion, near empty, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, reminder alarm, pressure sensor error, syringe installation error, syringe drop off |
| Additional Features | Real-time infused volume, automatic power switching, automatic syringe identification, mute key, purge, bolus, anti-bolus, system memory |
| Drug Library | Available |
| Occlusion Sensitivity | High, medium, low |
| Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
| Battery | 9.6±1.6 V, rechargeable |
| Battery Life | 7 hours at 5 ml/h |
| Working Temperature | 5-40℃ |
| Relative Humidity | 20-90% |
| Atmospheric Pressure | 860-1060 hpa |
| Size | 314*167*140 mm |
| Weight | 2.5 kg |
| Safety Classification | Class Ⅱ, type CF |